📋 Overview

The W115 230.4 commonly fails to start on first or second attempt when cold, especially below 10C. The engine cranks normally but does not fire, or fires briefly then stalls. This is almost universally a choke-related issue on the twin Zenith 35/40 INAT carburetors.

🩺 Symptoms
🔍 Possible Causes
🛠️ Diagnosis Steps
  1. Check choke flap position — should be nearly closed when cold.
  2. Test bimetal spring tension.
  3. Check choke pull-off diaphragm for cracks.
  4. Verify choke heater element resistance 40-60 ohms.
  5. Adjust choke if needed.
Most Confirmed Fix

Replace choke pull-off diaphragm and re-adjust choke bimetal spring. Clean choke housing.

78% of users confirm this fix worked (14 reports)
🏷️ Parts Needed

Zenith 35/40 INAT choke pull-off diaphragm kit